Features:
- Four Ring Conductivity Probe
- Compatible with pH/ORP/EC/DO Digital Probes
- CAL Check Feature
- Capacitative touch
- Clear Full Text Readout
- Large Easy to Read LCD
- Use as Portable, Benchtop of Wall-Mount
- Digital Electrodes Which Store Calibration Data
- Sensor Check
- 8 Hour Battery Life
- Dual USB Inputs
- Data Logging Up to 1000 Log Records
- Two Operating Modes
Specifications
pH:
- pH Range: -2.000 to 16.000 pH, -2.00 to 16.00 pH, 1000 mV
- pH Resolution: 0.001 pH, 0.01 pH, 0.1 mV
- pH Accuracy (@25 C/77 F): +/- m0.2 mV, +/- 0.01 pH, +/- 0.002 pH
- pH Calibration: up to 5 points
- pH Calibration Buffers: 1.68, 10.01, 12.45, 4.01, 6.86, 7.01, 9.18, two custom buffers
- pH Temperature Compensation ATC: -5.0 to 100.0 C; 23.0 to 212.0 F*
EC:
- EC Range: 0.00 to 29.99 uS/cm, 30.0 to 299.9 uS/cm, 300 to 2999 uS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
- EC Resolution: 0.01 ?S/cm, 0.1 uS/cm, 1 uS/cm, 0.01 mS/cm, 0.1 mS/cm
- EC Accuracy (@25 C/77 F): +/- 1% of reading (+/- 0.05 uS/cm or 1 digit, whichever is greater)
- EC Calibration: 1 point offset calibration (0.00 uS/cm in air), 1 point slope calibration in EC standard 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
- EC Temperature Compensation: ATC (0.0 to 100.0 C; 32.0 to 212.0 F), NoTC
TDS:
- TDS Range: 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
- TDS Resolution: 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
- TDS Accuracy (@25 C/77 F): +/- 1% of reading (+/- 0.03 ppm or 1 digit, whichever is greater)
- TDS Calibration: through EC calibration
- TDS Conversion Factor: 0.40 to 0.80
Salinity:
- Salinity Range: 0.0 to 400.0% NaCl, 2.00 to 42.00 PSU, 0.01 to 42.00 PSU, 0.0 to 80.0 g/L*
- Salinity Resolution: 0.1% NaCl, 0.01 PSU, 0.01 g/L
- Salinity Accuracy (@25 C/77 F): +/- 1% of reading
- Salinity Calibration: 1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)
DO:
- DO Range: 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
- DO Resolution: 0.01 ppm, 0.1% saturation
- DO Accuracy: +/- 1 digit, +/- 1.5% of reading
- DO Calibration: one or two points at 0% (HI 7040 solution) and 100% (in air)
- DO Temperature Compensation ATC: 0 to 50 C; 32.0 to 122.0 F
- Salinity Compensation: 0 to 40 g/L (with 1 g/L resolution)
- DO Altitude Compensation: -500 to 4000 m (with 100 m resolution)
Temperature:
- Temperature Range: -20.0 to 120.0 C, -4.0 to 248.0 F
- Temperature Resolution: 0.1 C, 0.1 F
- Temperature Accuracy: +/- 0.5 C, +/- 1.0 F
- pH Electrode Diagnostics: Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
- Logging: up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots)
- Connectivity: 1 micro USB port for charging and PC connectivity, 1 USB port for storage